DESIGN
OF RING BEAM/WALL AS PER IS:456-2000 PROGRAM INFO / LIMITATIONS: ( Actual program is available in Super Civil CD ) |
||||||||||||||||
Working stress method is used in design of ring wall foundation. | ||||||||||||||||
For members in direct tension when full tension is taken up by reinforcement alone, the tensile stress in concrete shall not be greater than the following. | ||||||||||||||||
|
||||||||||||||||
Minimum thickness of wall is considered as 150 MM. | ||||||||||||||||
Wind / seismic loads shall be carried by ring foundation alone. | ||||||||||||||||
Minimum horizontal steel shall be 0.20 %. | ||||||||||||||||
Minimum vertical steel shall be 0.12 %. | ||||||||||||||||
Spacing
of bars shall not exceed the least of following. 3 x wall thickness 450 MM. |
||||||||||||||||
Lap length for horizontal bars shall be 2 x Ld for tension. | ||||||||||||||||