SALIENT
FEATURES OF IS:13920 - 1993.
CODE OF PRACTICE FOR DUCTILE DETAILING OF RC STRUCTURES
SUBJECTED TO SEISMIC FORCES.
BEAM
DESIGN:
(
Actual program is available in
Super Civil CD ) |
SR |
DESCRIPTION |
1 |
Ductile
detailing is a must for structures in Zone IV & V. However it should
also be followed in zone III, when Importance factor is > 1.0
OR
Structure is > 5.0 Storey high OR the structure is industrial in
nature. |
2 |
Minimum
longitudinal reinforcement on any face/section shall be :
0.24 * sqrt (fck)/fy |
3 |
The
factored axial stress shall not be > 0.1 fck, else the beam should
be designed as column. |
4 |
B/D
> 0.30 preferably. |
5 |
B
should not be < 200 MM. |
6 |
The
maximum steel ratio should not be > 2.5 % per face. |
7 |
Beam
should not be a DEEP beam. |
8 |
+ve
reinforcement should not be < 50 % of -ve steel at that joint. |
9 |
Minimum
steel at any section face shall not be < 25 % of maximum -ve steel
at any joint. |
10 |
Re-distribution
of support moments are not allowed for seismic moments at joints. |
11 |
Development
length {Ld} = Ld + 10 x Ø at end joints of column/beam. |
12 |
Top
& bottom reinforcements shall be continuous at column joints. |
13 |
All
links shall be closed type, having a 135° hook with a 10 Ø extension,
but not less than 75 mm at each end. |
14 |
The
longitudinal bars shall be spliced, only if links are provided over
the entire splice length at spacing not > 150 MM. |
15 |
All
splice shall have Ld in tension. |
16 |
Lap
splice shall not be at :
Column
Joints.
2 x d
from column face.
Within
0.25 x span. |
17 |
Not
> 50 % of bars shall be spliced at any section. |
18 |
The
Minimum link Ø shall be 6 MM for span < 5.0 M.
Use 8 MM Ø links for span > 5.0 M. |
19 |
The
Links shall be designed for :
Factored SF as per Analysis.
SF due to formation of plastic hinges at both ends + gravity loads as
per analysis. |
20 |
Spacing
of Links within 2 x d from supports shall be minimum of :
d/4
8 x Ø of smallest longitudinal bar. |
21 |
Spacing
of links shall not be < 100 MM. |
22 |
1st
link shall start 50 mm away from support. |
23 |
Spacing
of links away from 2 x d from support shall not be > d÷ 2. |
24 |
Link
spacing shall not be > 300 MM. { As per IS-456-2000 }. |
25 |
The
top as well as bottom reinforcement shall atleast have 2 bars continuous
throughout the whole member. |
26 |
We
have restricted the beam section to an Under-Reinforced Section so that
they can undergo large rotation before failure. The contribution of
concrete towards shear strength is neglected. |
|