VERSION 2
( Full Rate Analysis Program + Specs in SRA )

Rate Analysis with latest Material and Labour rates for 08 - 2009.
 
58 Additional items included. Total items analyzed = 1294.

CPWD DSR included.

Kerala SOR 2008 added.

Standard Contract Document added.
  

FOLLOWING ITEMS ARE ADDED

PCC - > Section D

D37 - PCC 1:2:3.5:9 - FLYASH CONCRETE IN PLINTH
D38 - PCC 1:2.5:4:11 - FLYASH CONCRETE IN PLINTH
D39 - EXTRA FOR ADMIXTURE
---------------------------------------
RCC - > Section E

E66 - FORMWORK FOR CHIMNEY / SHAFT
E67 - FORMWORK FOR FINS / LOUVERS
E68 - EXPANSION JOINT - 125X 20 MM
E69 - JOINT FILLER - 125 X 12
E70 - EXPANSION JOINT - FIBER BOARD
---------------------------------------
Masonry - > Section F

F37 - EXTRA FOR REINFORCEMENT IN HALF BRICK MASONRY
F38 - AUTOCLAVED AERATED CEMENT BLOCK MASONRY
F39 - GYPSUM PANEL PARTITIONS
---------------------------------------
Roofing - > section M

M65 - THERMAL INSULATION OF CEILING
M66 - THERMAL INSULATION OVER EXISTING FALSE CEILING
M67 - THERMAL INSULATION OF ROOFING
------------------------------------------------------
Painting - > Section P

P44 - TEXTURED EXTERIOR PAINT
P45 - ACRYLIC SMOOTH EXTERIOR PAINT
P46 - ACRYLIC PAINT + SILICON ADDITIVE
P47 - DELUXE MULTI SURFACE PAINT
P48 - DELUXE MULTI SURFACE PAINT OVER WOOD
P49 - DELUXE MULTI SURFACE PAINT OVER STEEL
P50 - MORDENT SOLUTION WITH COPPER ACETATE
P51 - MORDENT SOLUTION WITH HCL
---------------------------------------------------
Dismantaling - > Section R

R70 - DISMANTLING ALUMINUM / GYPSUM PARTITIONS
-------------------------------------------------
Wood & PVC Works - > Section I

I54 - UPVC DOOR FRAME 48x40 / 42x50
I55 - PVC DOOR FRAME 50 x 47
I56 - 24 MM THICK PVC DOOR SHUTTER
I57 - 30 MM THICK PVC DOOR SHUTTER
I58 - PVC RIGID FOAM SHEET
--------------------------------------------------
Roads - > Section T
 
T87 - GLOW STUDS 100 x 20
T88 - CONCERTINA COIL FENCING
T89 - MANDATORY RETRO REFLECTIVE SIGN BOARD
T90 - WARNING RETRO REFLECTIVE SIGN BOARD
T91 - OVERHEAD INFORMATORY ROAD SIGNAGE
T92 - REGULATORY RETRO REFLECTIVE SIGN BOARD
T93 - RETRO REFLECTIVE ROAD MARKING STRIPS
T94 - PRECAST RCC PAVEMENT SLAB
T95 - CONCRETE INTERLOCKING PAVER BLOCKS
T96 - PVC COATED G. I. CHAIN LINK FENCING
T97 - SCARIFYING EXISTING BITUMINOUS ROAD
--------------------------------------------------
Water Supply - > Section W

W145 - POLYETHELENE - ALUMINUM - POLYETHELENE PIPE
W146 - POLYETHELENE - RANDOM - COPOLYMER PIPE
W147 - CHLORINATED POLYVINYL CHLORIDE PIPE
W148 - SUPPLY OF PIG LEAD AT SITE
--------------------------------------------------
Piles - > Section Y

Y17 - 750 MM Ø RCC CAST IN SITU DRIVEN PILES
Y18 - 1000 MM Ø RCC CAST IN SITU DRIVEN PILES
Y19 - 1200 MM Ø RCC CAST IN SITU DRIVEN PILES
Y20 - 1500 MM Ø RCC CAST IN SITU DRIVEN PILES
Y21 - 500 MM Ø RCC BORED CAST IN SITU PILES
Y22 - 750 MM Ø RCC BORED CAST IN SITU PILES
Y23 - 1000 MM Ø RCC BORED CAST IN SITU PILES
Y24 - 1200 MM Ø RCC BORED CAST IN SITU PILES
Y25 - 1500 MM Ø RCC BORED CAST IN SITU PILES
Y26 - EXTRA OVER ITEM Y9 FOR ADDITIONAL BULB
Y27 - EXTRA OVER ITEM Y10 FOR ADDITIONAL BULB
Y28 - EXTRA OVER ITEM Y11 FOR ADDITIONAL BULB
Y29 - EXTRA OVER ITEM Y12 FOR ADDITIONAL BULB
Y30 - 750 MM Ø RCC PRE CAST DRIVEN PILES
Y31 - 1000 MM Ø RCC PRE CAST DRIVEN PILES