SPLICE OF STRUCTURAL STEEL SECTIONS
( Following details are included in Super Civil CD )

1 SPLICE DETAILS OF UN EQUAL SINGLE ANGLES
2 SPLICE DETAILS OF EQUAL SINGLE ANGLES
3 SPLICE DETAILS OF EQUAL DOUBLE  ANGLES
4 SPLICE DETAILS OF UN EQUAL DOUBLE ANGLES
5 SPLICE DETAILS OF MB MEMBERS
6 SPLICE DETAILS OF MC MEMBERS

                                  

ALL DIMENSIONS ARE IN MMS.
ALL BUTT WELDS ARE FULL STRENGTH WELDS.
ALL EDGES SHALL BE PREPARED BEFORE BUTT WELDING.
SPLICE PLATES ARE DESIGNED FOR 40 % OF FULL STRENGTH OF THE MEMBER.
SPLICES SHALL NOT BE LOCATED AT THE POINT OF MAXIMUM BENDING MOMENT & OR MAXIMUM SHEAR FORCE.
SPLICE PLATES MAY BE OMITTED FOR PURLINS & SIDE RUNNERS FOR MEMBER SIZE UP TO 150 mm DEPTH.
BUTT WELD SHALL BE SINGLE " V " BUTT WELD FOR THICKNESS LESS THAN 16 mm & DOUBLE " V " BUTT WELD FOR THICKNESS EQUAL TO OR MORE THAN 16 mm.